Connecting of the Cable
4. Connecting of the Cable
Indoor Unit
1. Connect indoor unit wiring according to wiring diagram given in manual.
Outdoor Unit
- ♦Connect the power cord to the outdoor unit by connecting wires to the terminal control board.
- ♦Remove the access door from the unit by loosening the screw. Connect the wires to the terminal on the control board individually as the following.
- ♦Secure the power connecting cord onto the control board with cable clamp.
- ♦Reinstall the access door to the original position with the screw.
- ♦Use a recognized circuit breaker between the power source and the unit. A disconnection device to adequately disconnect all supply line must be fitted.
Caution:
- 1.Never fail to have an individual power circuit specifically for the air conditioner. As for the method of wiring, refer to the circuit diagram posted on the inside of the access door.
- 2.Confirm that the cable thickness is as specified in the power source specification.
- 3.Check the wires and make sure that they are all tightly fastened after cable connection.
- 4.Be sure to install an earth leakage circuit breaker in wet or moist area.
- 5.ODU rubber pad to be used during installation to avoid vibration and noise.
CAUTION
- ♦Do not use tapped wires, extension cords, or starburst connections, as they may cause overheating, electric shock, or fire.
- ♦Do not use locally purchased electrical parts inside the product. Do not branch the power for the drain pump, etc., from the terminal block. Doing so may cause electric shock or fire.
- ♦Do not connect the power wire to the indoor unit. Doing so may cause electric shock or fire.