Air Conditioner Operating Modes
Cool, Dry, and Fan mode
Cool Mode
- ♦In this mode, the compressor cools the air by taking hot air out and blowing cold air inside the room.
- ♦This is the most energy intensive mode on AC.
- ♦Temperature can be varied from 16°C to 30°C by pressing Up/Down keys.
- ♦Fan speed can be varied by pressing fan speed key in the sequence of Low > Med > High > Auto in a cyclic way.
- ♦ECO function can be enabled or disabled by ECO key.
Following 24°C logic is applicable when AC is operated in Cool mode:
- If user has set the temperature below 24°C in Cool mode prior to switching off AC and then if AC is turned on by Remote, AC will start operating at 24°C temperature only.
- If user has set the temperature 24°C or above 24°C in Cool mode prior to switching off AC and then if AC is turned on by Remote, AC will start operating at previous set temperature by user.
Dry Mode
- ♦Set temperature will be 24°C by default and it cannot be varied by pressing temp. up/down keys.
- ♦Fan speed is fixed to low speed and cannot be varied.
- ♦Turbo mode cannot be set.
- ♦Silent mode cannot be set.
- ♦Display can be enabled or disabled by pressing Dim key.
- ♦Timer off can be enabled or disabled by pressing Timer off key.
- ♦Swing can be enabled or disabled by pressing swing key.
- ♦Clean/Eco function cannot be enabled or disabled.
Fan Mode
- ♦IOU display will show room temperature in Fan Mode and it cannot be varied by pressing temp. up/down keys.
- ♦Fan speed can be varied by pressing fan speed key in the sequence of Low > Med > High in a cyclic way and Auto fan speed cannot be set.
- ♦Sleep mode cannot be set by pressing sleep key.
- ♦Silent mode cannot be set.
- ♦Eco mode cannot be set.
- ♦Timer off can be enabled or disabled by pressing Timer off key.
- ♦Swing can be enabled or disabled by pressing swing key.