Air Conditioner Operating Modes

Cool, Dry, and Fan mode

Cool Mode

  • In this mode, the compressor cools the air by taking hot air out and blowing cold air inside the room.
  • This is the most energy intensive mode on AC.
  • Temperature can be varied from 16°C to 30°C by pressing Up/Down keys.
  • Fan speed can be varied by pressing fan speed key in the sequence of Low > Med > High > Auto in a cyclic way.
  • ECO function can be enabled or disabled by ECO key.

Following 24°C logic is applicable when AC is operated in Cool mode:

  • If user has set the temperature below 24°C in Cool mode prior to switching off AC and then if AC is turned on by Remote, AC will start operating at 24°C temperature only.
  • If user has set the temperature 24°C or above 24°C in Cool mode prior to switching off AC and then if AC is turned on by Remote, AC will start operating at previous set temperature by user.

Dry Mode

  • Set temperature will be 24°C by default and it cannot be varied by pressing temp. up/down keys.
  • Fan speed is fixed to low speed and cannot be varied.
  • Turbo mode cannot be set.
  • Silent mode cannot be set.
  • Display can be enabled or disabled by pressing Dim key.
  • Timer off can be enabled or disabled by pressing Timer off key.
  • Swing can be enabled or disabled by pressing swing key.
  • Clean/Eco function cannot be enabled or disabled.

Fan Mode

  • IOU display will show room temperature in Fan Mode and it cannot be varied by pressing temp. up/down keys.
  • Fan speed can be varied by pressing fan speed key in the sequence of Low > Med > High in a cyclic way and Auto fan speed cannot be set.
  • Sleep mode cannot be set by pressing sleep key.
  • Silent mode cannot be set.
  • Eco mode cannot be set.
  • Timer off can be enabled or disabled by pressing Timer off key.
  • Swing can be enabled or disabled by pressing swing key.